Wiring harness in corrugated loom. Photo from DiCAN’s Plow Pilot PWM Tow Plow guide, v1.4.


A camera, communications system or telematics module depends on the wiring that powers it and carries its data. On a work vehicle in Québec, that wiring faces road salt, water, vibration, moving equipment and wide temperature swings. Protection starts at installation and needs attention throughout the vehicle’s service life.


A little chafing can eventually cause a failure


A cable may work at first and then wear through where it rubs against a bracket or an edge. A loose fastener, a harness under tension or a run too close to a heat source can eventually damage the cable jacket. If moisture and contaminants reach the conductors or a poorly protected connection, corrosion can spread. Water can also wick along the wire strands and cause damage beyond the visible spot.


Symptoms can come and go. A camera feed may cut out, a device may restart or data may go missing. Any of these symptoms warrants a closer look. Along with the wiring, check the power supply, the equipment and, where applicable, the communications link.


Choosing wire loom for mechanical protection


Corrugated tubing, often called wire loom, helps protect against chafing and other mechanical damage. It keeps the harness organized, but it still needs a suitable route and secure mounting points. Ordinary split loom alone does not seal a connection against salt water.


Consider the harness diameter, how much it moves and the conditions along its route. Check the operating temperature range, the minimum installation temperature, resistance to chemicals the loom may encounter and, for exposed sections, UV resistance. Black looms that look alike can have different ratings. A tight fit, an unprotected end or a loose section can leave part of the harness vulnerable.


Match each protective measure to the exposure

These DiCAN harnesses show how corrugated loom, labels and protection at the ends fit together. The choice of materials and sealing method still needs to be checked for each installation.


DiCAN harnesses with connectors, function labels and black protective sleeves at the ends.

Labelled harnesses with protection at the ends. Source: DiCAN Plow Pilot PWM guide, v5.0, photo on page 12 of SSB’s French edition.



  • Chafing and vibration: Use suitable loom or abrasion-resistant sleeving, stable supports and fasteners that secure the harness without crushing the jacket.

  • Passing through sheet metal: Fit a grommet or edge guard sized to prevent contact with the metal edge. Seal the opening separately wherever the installation requires it.

  • Connections exposed to salt water: Use sealed connectors or an approved connection method, with seals, plugs and tools matched to the wires.

  • Splices suitable for adhesive-lined tubing: Select and apply adhesive-lined heat-shrink tubing according to its data sheet. A sleeve can look closed even if the seal is incomplete.

  • Hot areas: Route the harness away from the heat source. Add dedicated heat protection if the route assessment calls for it.


Covering an already damaged cable does not restore its electrical integrity. Assess the extent of the damage and follow the repair or replacement procedure for that harness. Camera, data and antenna cables may require manufacturer-specific connectors and procedures.


Assess heat exposure separately


Even in cold weather, the engine and exhaust create hot spots. Check the loom’s temperature rating against the actual exposure, taking continuous heat, intermittent heat and radiant heat into account. The cable inside the loom has its own temperature rating.


High-temperature sleeving and reflective shielding each serve a particular purpose. Even with either one fitted, keep the harness clear of hot components. Follow the vehicle and equipment manufacturers’ requirements for routing, clearance and movement.


Adapt the installation to the way the fleet works


Drivers know the manoeuvres and operating conditions. Maintenance staff know the recurring repairs and access points. Vehicle manufacturers, suppliers and engineers identify the technical constraints. Fleet managers and telematics partners define which data they need and how they will use it.


Électronique SSB supplies the products and InstallaFex handles installation. InstallaFex works with these people to translate operating needs into routing, mounting and protection choices everyone understands, then agrees with them on what to check. For a Geotab integration with AttriX or another partner, that coordination also helps connect an issue observed on the vehicle with the data received by the platform.


Plan for inspection and maintenance


Before the season and at intervals appropriate to vehicle use, inspect exposed areas for open loom, chafing, heat deformation, missing fasteners and deteriorating connections. After a repair or modification, check that the harness stays secure through its expected range of movement. Set the inspection interval with the maintenance team, taking the manufacturers’ recommendations into account.



Technical references


Guidance on choosing and applying protection: HellermannTyton corrugated conduit, grommets and edge protection, TE Connectivity guidance on splice protection and moisture migration, ABB high-temperature conduit systems. Specifications apply to the listed products and documented conditions. Check them against the vehicle’s actual configuration.


Frequently asked questions about winter vehicle wiring

Does corrugated loom protect a connection from salt water?

Split corrugated loom mainly protects the harness against chafing. For a connection exposed to spray, also use a sealed connector or a connection method approved for the wires involved.

My camera feed cuts out intermittently. What should I tell the shop?

Note when the image disappears, for example when a piece of equipment moves. Report any visible chafing, loose fasteners or signs of corrosion. Those details help the shop decide what to check on the harness, the power supply and the camera.

Where should we look first before winter?

Inspect sheet-metal pass-throughs, moving sections, connections exposed to spray and runs near the engine or exhaust. If an accessory has moved since last season, have the harness routing checked in its new position.

Plan wiring protection for your vehicles